Chlamydia trachomatis IgM and IgG

After infection with Chlamydia trachomatis, specific IgM antibodies can be detected in the serum and tears of the patient, and the positive suggestive of recent infection with Chlamydia trachomatis can make an early diagnosis. IgG antibodies appear later and last longer, and the antibody is positive for retrospective diagnosis and epidemiological investigation. Basic Information Specialist classification: Infectious disease inspection and classification: pathogenic microorganism inspection Applicable gender: whether men and women apply fasting: fasting Analysis results: Below normal: Normal value: no Above normal: negative: IgM is less than 1:32 and IgG is less than 1:2000 negative. Positive: Positive: IgM>1:32 and IgG>1:2000: active sexually transmitted diseases, lymphogranuloma. Tips: Please cooperate with the doctor when checking. Normal value IgM<1:32; IgG < 1:2000. Clinical significance IgM>1:32 and IgG>1:2000, active sexually transmitted diseases, lymphogranuloma. Positive results may be diseases: precautions for chlamydia pneumonia in children Patients often develop IgM only after 3 weeks of onset, and IgG is detected 6 to 8 weeks later. Inspection process (1) Titration of complement and hemolysin. 1 Take 1ml of complement, add 9ml of BBS, and then dilute to 1:20, 1:30, 1:40, 1:50, 1:60, 1:80, 1:100, 1:200, 1:400, and take 50 0.2 ml of hemolysin, add 9.8 ml of BBS, which is 1:100 hemolysin, and then continue to dilute to 1:800, 1:1600, 1:3200, 1:6400. 2 Take the square array of test tubes, longitudinally add 0.1ml of different concentrations of complement, and add 0.1ml of hemolysin in each row (all should be added from the highest dilution), then add BBS0.2ml, complement and The hemolysin control tubes were each added with BBS 0.3 ml, and finally 2% sheep red blood cells were added to each tube. The total amount of each tube was 0.5 ml, shaken, placed in a 37 ° C water tank for 30 min, and the results were observed. Here is an example: The highest dilution of complete hemolyzed complement and hemolysin is the respective unit. 1:3200 is a hemolysin unit, and complement 1:80 is a complement unit. In practical applications, the hemolysin is 2u (3200÷2=1600) and the complement is 2.5u (80÷2.5=32). (2) Formal test: 1 Operate with a V-type microplate, each specimen was made into one test well and one serum control well. BBS0.025ml was added to each well. 2 Dip serum (0.025 ml) with a dilution stick to the first well, rotate and transfer to the second well for a total of eight wells, thus obtaining a 1:2 to 1:256 dilution. (3) Judgment of results: The results of each tube of the control group should meet the following conditions, otherwise it should be redone. Complement control tube: 2.5u = 0, 1u = 0 ~ ±, 0.5u = 3 ~ 4. Sheep red blood cell control tube: 4. Antibody control tube: 0. Negative control tube; 1:2 to 1:256=0. Positive control tube: the same positive serum, the results should be consistent. When the reaction tube of each measuring tube is the strongest, one tube is still ± report suspicious, and 1 to 4 reports positive. If both the measuring tube and the serum control tube are anti-complement, all the measuring tubes are 0, and the report is negative. The method of examining the antibody is the same as the method of examining the antigen, except that four units of known antigen are used instead to determine the serum to be tested. Not suitable for the crowd Those who do not have an indication for examination should not do this check. Adverse reactions and risks Generally no complications and harm.

The material in this site is intended to be of general informational use and is not intended to constitute medical advice, probable diagnosis, or recommended treatments.

Was this article helpful? Thanks for the feedback. Thanks for the feedback.